Weber, Hayes and Associates was retained to complete the permitted closure of an abandoned gasoline underground storage tank (UST). Upon UST 
- Assisting the responsible party with a State UST Cleanup Fund grant application which resulted in a $1.5M grant award for site assessment and remediation.
- Correspondence and close coordination with Central Coast Regional Water Quality Control Board staff (lead agency) for all site assessment and remediation tasks.
- Complete characterization of chemical impacts to all affected media (i.e., soil, soil vapor, groundwater, and surface water) via soil borings, monitoring wells and geologic outcrop reconnaissance along a nearby stream course.
- Contaminated soil source removal via large diameter augers and off-site disposal.
- In-situ subsurface injection of ~26,000 lbs of a chemical oxidant reagent for hydrocarbon concentration reduction.
- Design and completion of a successful soil vapor extraction (SVE) and air sparge (AS) pilot test and preparation a full-scale SVE / AS Remedial Action Plan.